Friday, August 12, 2011

FIVE O&G SPILL(S) OF THE DAY - NOBLE ENERGY PRODUCTION INC WELD COUNTY COLORADO

The 15th annual selections were announced Aug 3rd 2011 at the Colorado Oil and Gas Association's annual conference. One of the environmental protection category winners was: Noble Energy Inc. -- Employed closed-loop systems at all 600 wells drilled statewide in 2010. The move has eliminated reserve pits, reduced land use impacts, sped up land reclamation and resolved concerns associated with hard to dispose of pit liners.

We'd really like people to know that Noble energy had seven reported spills this week in Weld County alone. In the formula that is used for selection,  does the COGCC evaluate the number of contaminant spills a company has had for the year?  Is one part of the formula: total volume of contaminant spilled versus the amount recovered?  Do spills on feed lots carry extra weight as far as not being selected for the COGCC award?  What about contaminant discharges in both moving and standing bodies of water? Does a company lose points when that happens? The concerned citizens would like to know why your selection algorithm does not include these very basic issues?

It appears that the formula to select an O&G company under any category appears to be hyperbole. Right back at ya' Gov.  A self-purported 'scientific' industry lacks evaluation criteria to choose the good, the bad and the ugly operators in a comprehensive meaningful and accurate fashion. We urge you to create a scientifically fair formula that addresses operator impacts, groundwater contaminations, surface contaminations, human health impacts, repeat spill incidents, alleged notices of violations, lack of wildlife mitigation procedures, faulty equipment, and numerous other variables.

We also urge the state to impose monumental fines for all violations.  We are not talking about your tiny 'in-place' fines of $1,000 -$5,000.  There have been numerous companies that have both accidentally and  purposefully discharged contaminants thus contaminating the surface and groundwater  just like the O&G industry may have, and those polluters have been fined several hundreds of thousands of dollars.  Your imposed fines are arbitrary, weak, and do nothing in regards to punishing a very wealthy industry.  Each violation should start out large and get even larger when an operator is a repeat offender. 

That's not hyperbole.

 
SPILL #1

Date Rec'd: 8/11/2011 Report taken by: JOHN AXELSON
DocNum: 2215313 API number: 05-123 -33202 Facility ID: 422231

Operator Information

Operator: NOBLE ENERGY PRODUCTION INC Oper. No. 10120
Address: 1625 BROADWAY STE 2200 ATTN: TED BROWN DENVER , CO 80202
Phone: (303 )389-3600 Fax: (303 )595-7403
Operator Contact: TODD CULLUM

Description of Spill:

Date of Incident: 8/7/2011
Type of Facility: WELL
Well Name/No. WELLS RANCH AA 12-08 Fac. Name/No.
County Name: WELD
qtrqtr: SENE section: 12 township: 6N range: 63W meridian: 6

<><><><>
Volumes spilled and recovered (bbls) (bbls= barrel. 1 barrel = 42 US Gallons)
Oil spilled: 127Recvrd: 117 420 GALLONS UNRECOVERED
Water spilled: 0 Recvrd: 0
Other spilled: Recved:
GW Impact? N Surface water impact? N Contained within berm? Y
Area and vertical extent of spill: - X -
Current land use: PASTURE
Weather conditions: CLEAR, HOT
Soil/Geology description VONA LOAMY SAND
Distance in feet to nearest surface water:
Depth to shallowest GW:
Wetlands: Buildings:
Livestock: Water Wells:
Cause of spill:
HUMAN ERROR
Immediate Response:
PUMPER SHUT WELL IN, CALLED FOR A VAC TRUCK WHICH RECOVERED 117 BBLS, BEGAN DISMANTLING THE TANK TO BEGIN EXCAVATION.
Emergency Pits:
N/A
How extent determined:
VISUAL, EXCAVATION OF IMPACT WILL BE DELINEATED WITH HANBY FIELD TEST KIT AND LAB CONFIRMATION SAMPLES WILL BE COLLECTED.
Further Remediation
IMPACTED SOILS WILL BE EXCAVATED AND TAKEN TO THE NORTH WELD SANITARY LANDFILL, AULT, CO.
Prevent Problem:
PUMPER WAS REPRIMANDED FOR NOT PUTTING THIS WELL ON THE WEEKEND CHECK LIST.
Detailed Description:
300 BBL OIL PRODUCTION TANK OVERFILLED OVER THE WEEKEND RELEASING 127 BBLS OIL INTO DIRT BERM.


Other Notifications
Date Agency Contact Response
8/9/2011 COGCC JOHN AXELSON LEFT JOHN A MESSAGE



Field Visit/Follow Up
Name Phone Date
No Field Visit data found.


















SPILL# 2

AMOUNT SPILLED: UNKNOWN
 GROUNDWATER IMPACTED: YES
Amount of contaminant spilled: UNKNOWN

Date Rec'd: 8/11/2011 Report taken by: JOHN AXELSON
DocNum: 2215312 API number: 05-123 -14056 Facility ID: 246259

Operator Information

Operator: NOBLE ENERGY PRODUCTION INC Oper. No. 10120
Address: 1625 BROADWAY STE 2200 ATTN: TED BROWN DENVER , CO 80202
Phone: (303 )389-3600 Fax: (303 )595-7403
Operator Contact: TODD CULLUM

Description of Spill:

Date of Incident: 8/9/2011
Type of Facility: WELL
Well Name/No. WILLIAMS PM F 15-8 Fac. Name/No.
County Name: WELD
qtrqtr: SENE section: 15 township: 5N range: 65W meridian: 6

<><><><> <><><><>
Volumes spilled and recovered (bbls) (bbls= barrel. 1 barrel = 42 US Gallons)
Oil spilled: Recvrd:
Water spilled: Recvrd:
Other spilled: Recved:
GW Impact? Y Surface water impact? N Contained within berm? N
Area and vertical extent of spill: - X -
Current land use: PASTURE
Weather conditions: CLEAR, HOT
Soil/Geology description AQUALLS & AQUENTS, GRAVELLY SUBSTRATUM, 0-3% SLOPE
Distance in feet to nearest surface water: 180
Depth to shallowest GW: 3
Wetlands: Buildings: 190
Livestock: Water Wells: 850
Cause of spill:
EQUIPMENT FAILURE
Immediate Response:
TANK BATTERY HAD BEEN SHUT IN PRIOR TO BEGINNING WORK. CEMENT WATER VAULT HAD BEEN SUCKED DRY.
Emergency Pits:
N/A
How extent determined:
EXCAVATION OF IMPACT WILL BE DELINEATED WITH HANBY FIELD TEST KIT AND LAB CONFIRMATION SAMPLES WILL BE COLLECTED.
Further Remediation
IMPACTED SOILS WILL BE EXCAVATED AND TAKEN TO THE NORTH WELD SANITARY LANDFILL, A GROUNDWATER AMENDMENT WILL BE ADDED AND MONITORING WELLS WILL BE PLACED.
Prevent Problem:
BATTERY WILL BE RECONSTRUCTED WITH NEW OIL AND WATER LINES AND WATER VAULTS.
Detailed Description:
DURING BATTERY UPGRADE IT WAS FOUND THAT THE CEMENT WATER VAULT HAD DEVELOPED A LEAK.


Other Notifications
Date Agency Contact Response
8/10/2011 COGCC JOHN AXELSON LEFT MESSAGE AT 1535 MT


Field Visit/Follow Up
Name Phone Date
No Field Visit data found.











































SPILL#3

Date Rec'd: 8/11/2011 Report taken by: JOHN AXELSON
DocNum: 2215311 API number: 05-123 -12989 Facility ID: 245194

Operator Information

Operator: NOBLE ENERGY PRODUCTION INC Oper. No. 10120
Address: 1625 BROADWAY STE 2200 ATTN: TED BROWN DENVER , CO 80202
Phone: (303 )389-3600 Fax: (303 )595-7403
Operator Contact: TODD CULLUM

Description of Spill:

Date of Incident: 8/3/2011
Type of Facility: WELL
Well Name/No. LARSEN 1 Fac. Name/No.
County Name: WELD
qtrqtr: NENE section: 32 township: 6N range: 64W meridian: 6

<><><><>
Volumes spilled and recovered (bbls) (bbls= barrel. 1 barrel = 42 US Gallons)
Oil spilled: 90 bbls, or 3,780 gallonsRecvrd: 62  bbls or 2,604gallons 


Approx. 1,176 gallons of contaminants  unrecovered


Water spilled: 0











Recvrd: 0
Other spilled: Recved:
GW Impact? N Surface water impact? N Contained within berm? Y
Area and vertical extent of spill: - X -
Current land use: AGRICULTURE
Weather conditions: CLEAR, DRY AND HOT
Soil/Geology description KIM LOAM, 1-3% SLOPES
Distance in feet to nearest surface water: 4775
Depth to shallowest GW:
Wetlands: Buildings: 1500
Livestock: Water Wells: 1000
Cause of spill:
HUMAN ERROR
Immediate Response:
PUMPER SHUT THE WELL IN AND CALLED FOR A VAC TRUCK. VAC TRUCK RECOVERED 62 BBLS AND PUT IT INTO THE 2ND TANK ON SITE.
Emergency Pits:
N/A
How extent determined:
EXCAVATION OF IMPACT WILL BE DELINEATED WITH HANBY FIELD TEST KIT AND LAB CONFIRMATION SAMPLES WILL BE COLLECTED.
Further Remediation
IMPACTED SOILS WILL BE EXCAVATED AND TAKEN TO NORTH WELD SANITARY LANDFILL.
Prevent Problem:
PUMPER WAS REPRIMANDED FOR NOT OPENING THE THIEF HATCH WHILE UNLOADING THE WELL INTO THE TANK.
Detailed Description:
PUMPER OVER PRESSURED 300 BBL OIL PRODUCTION TANK WHILE UNLOADING THE WELL AND THE 4" X 2" SWEDGE ON THE BACK DRAIN LINE SPLIT, CAUSING THE OIL IN THE TANK TO LEAK INTO DIRT BERM.


Other Notifications
Date Agency Contact Response
8/4/2011 COGCC JOHN AXELSON LEFT JOHN MESSAGE ON VOICE MAIL 0954 MT


Field Visit/Follow Up
Name Phone Date






















SPILL#4

Date Rec'd: 8/11/2011 Report taken by: JOHN AXELSON
DocNum: 2215310 API number: 05-123 -33324 Facility ID: 422611

Operator Information

Operator: NOBLE ENERGY PRODUCTION INC Oper. No. 10120
Address: 1625 BROADWAY STE 2200 ATTN: TED BROWN DENVER , CO 80202
Phone: (303 )389-3600 Fax: (303 )595-7403
Operator Contact: TODD CULLUM

Description of Spill:

Date of Incident: 8/4/2011
Type of Facility: WELL
Well Name/No. WELLS RANCH USX AE 29-68HN Fac. Name/No.
County Name: WELD
qtrqtr: NWNW section: 29 township: 6N range: 62W meridian: 6

<><><><> <><><><>
Volumes spilled and recovered (bbls)
Oil spilled: 4Recvrd: 1 BARREL, 42 GAL UNRECOVERED
Water spilled: 20Recvrd: 15   5 BARRELS, 210 GAL UNRECOVERED




Other spilled:
Recved:
GW Impact? N Surface water impact? N Contained within berm? N
Area and vertical extent of spill: 50-FT X 150 -FT
Current land use: PASTURE
Weather conditions: CLEAR, HOT, HEAVY RAIN NIGHT BEFORE
Soil/Geology description OLNEY LOAMY SAND
Distance in feet to nearest surface water:
Depth to shallowest GW:
Wetlands: Buildings:
Livestock: Water Wells:
Cause of spill:
HUMAN ERROR
Immediate Response:
WAITED FOR THE WELL TO DIE ENOUGH TO BEGIN PUMPING MORE KCL DOWN HOLE TO FINISH KILLING THE WELL.CALLED FOR 3 VAC TRUCKS AND HOISTED THE RIG OFF. DUE TO A SIGNIFICANT AMOUNT OF RAIN THE NIGHT BEFORE THE GROUND WAS SATURATED AND HAD NUMEROUS WATER PUDDLES ON LOCATION, THE VAC TRUCKS SUCKS UP ALL OF THE STANDING WATER AND OIL.
Emergency Pits:
N/A
How extent determined:
VISUAL, SOIL SAMPLES WILL BE TAKEN AND REMEDIATION WILL COMMENCE WHEN FINISHED WORKING ON THE WELL.
Further Remediation
SOIL SAMPLES WILL BE TAKEN FROM THE SPILL AREA AND TESTED FOR BTEX AND TPH, THE REMEDIATION WILL BE DRIVEN BY THE RESULTS OF THESE TESTS.
Prevent Problem:
CONFIRM THE WELL IS DEAD BY PUMPING MORE KCL WATER DOWN HOLE.
Detailed Description:
WHILE NIPPLING UP THE BOP`S THE WELL CAME AROUND RESULTING IN THE WELL TO BLOW OUT 20 BBLS OF KCL WATER AND 4 BBLS OF OIL.


Other Notifications
Date Agency Contact Response
8/5/2011 COGCC JOHN AXELSON LEFT MESSAGE AT 1220 MT


Field Visit/Follow Up
Name Phone Date
No Field Visit data found














































SPILL#5

GROUNDWATER IMPACTED: YES

Date Rec'd: 8/11/2011 Report taken by: BOB CHESSON
DocNum: 2215307 API number: 05-123 -12393 Facility ID: 244598

Operator Information

Operator: NOBLE ENERGY PRODUCTION INC Oper. No. 10120
Address: 1625 BROADWAY STE 2200 ATTN: TED BROWN DENVER , CO 80202
Phone: (303 )389-3600 Fax: (303 )595-7403
Operator Contact: TODD CULLUM

Description of Spill:

Date of Incident: 8/5/2011
Type of Facility: TANK BATTERY
Well Name/No. SHELTON RG 26-7 Fac. Name/No.
County Name: WELD
qtrqtr: SWNE section: 26 township: 4N range: 65W meridian: 6

Volumes spilled and recovered (bbls)
Oil spilled: Recvrd:
Water spilled: Recvrd:
Other spilled: Recved:
GW Impact? Y Surface water impact? N Contained within berm? N
Area and vertical extent of spill: - X -
Current land use: FEED LOT
Weather conditions: CLEAR, DRY, HOT
Soil/Geology description OLNEY FINE SANDY LOAM, 1-3% SLOPES
Distance in feet to nearest surface water: 1635
Depth to shallowest GW: 10
Wetlands: Buildings: 650
Livestock: Water Wells: 620
Cause of spill:
EQUIPMENT FAILURE
Immediate Response:
TANK BATTERY HAD BEEN SHUT IN PRIOR TO BEGINNING WORK. CEMENT WATER VAULT HAD BEEN EMPTIED.
Emergency Pits:
N/A
How extent determined:
EXCAVATION OF IMPACT WILL BE DELINEATED WITH HANBY FIELD TEST KIT AND LAB CONFIRMATION SAMPLES WILL BE COLLECTED.
Further Remediation
IMPACTED SOILS WILL BE EXCAVATED AND TAKEN TO THE BUFFALO RIDGE LANDFILL IN KEENSBURG, CO. DURING EXCAVATION A WATER AMENDMENT WILL BE ADDED AND GROUND WATER MONITORING WELLS WILL BE INSTALLED.
Prevent Problem:
BATTERY WILL BE RECONSTRUCTED WITH NEW OIL AND WATER LINES AND WATER VAULT.
Detailed Description:
DURING BATTERY UPGRADE IT WAS FOUND THAT THE CEMENT WATER VAULT HAD DEVELOPED A LEAK.


Other Notifications
Date Agency Contact Response
8/5/2011 COGCC ROBERT CHESSON LEFT MESSAGE 1205 MT


Field Visit/Follow Up
Name Phone Date
No Field Visit data found.




















------------------------------


2 comments:

  1. Who owns the land where the groundwater was impacted? What was added to the groundwater - an amendment? Was the soil tested to determine if it is now hazardous waste? Solid waste landfills should not receive hazardous waste!

    ReplyDelete

WTFrack.org is a medium for concerned citizens to express their opinions in regards to 'Fracking.' We are Representatives of Democracy. We are Fractivists. We are you.

CAST YOUR VOTE